Symptom Probable Cause Solution
Water overflows the Float valve stuck or failed. Adjust or replace the float valve.
level control housing
when the distiller if off.
Water overflows the Blockage in the boiler outlet or Replace or modify blocked part.
level control housing condensing tubing or connector.
when the heater is on.
Water in level control Restrictor blockage. Clean and replace.
housing, but not in
boiling chamber.
Dirt in raw water tank. Excess sediment in feed water. Clean Tank. Install a sediment filter
in the water line before the
mini-softener.
Water overflows or Float valve in dispenser is Adjust or replace float valve.
leaks from dispenser. obstructed or faulty valve.
Dispenser not cooling. Coolant gone from compressor. Remove and deliver to dispenser
manufacturer's approved service
center.